PETROLEUM PRODUCT TESTING > REDWOOD VISCOMETER

  • Redwood Viscometer

Redwood Viscometer

REDWOOD VISCOMETER NO.1
  • With Energy Regulator
  • With Gas Burnor
  • With Voltage Varriar
  • With Digital Indicator & Controller
WITH ENERGY REGULATED: AS PER IP-70 & IS 1448 Used for determination of viscosity of all oils the viscosity of which at the temperature of test does not exceed 2000 seconds The complete outfit comprises Hammertone finish, Copper/Stainless steel bath with drain plug, electrical heating arrangement, with silver plated oil cup with precision stainless steel jet, ball valve, cover, thermometer clip, stirrer and suitable stand with levelling screws. Electric Heated with separate energy regulator control.
WITH GAS BURNOR: Same as above but with Gas Burner
WITH VOLTAGE VARRIAR: AS PER IP-70 & IS 1448 Used for determination of viscosity of all oils the viscosity of which at the temperature of test does not exceed 2000 seconds The complete outfit comprises Hammertone finish, Copper/Stainless steel bath with drain plug, electrical heating arrangement, with silver plated oil cup with precision stainless steel jet, ball valve, cover, thermometer clip, stirrer and suitable stand with levelling screws. Electric Heated voltage variac copper coil type.
WITH DIGITAL INDICATOR & CONTROLLER AS PER IP-70 & IS 1448 Used for determination of viscosity of all oils the viscosity of which at the temperature of test does not exceed 2000 seconds The complete outfit comprises Hammertone finish, Copper/Stainless steel bath with drain plug, electrical heating arrangement, with silver plated oil cup with precision stainless steel jet, ball valve, cover, thermometer clip, stirrer and suitable stand with levelling screws. Electric Heated Model with Digital temperature controller cum indicator.
REDWOOD VISCOMETER NO.2:
  • With Energy Regulator
  • With Gas Burnor
  • With Voltage Varriar
  • With Digital Indicator & Controller
per IS 1448 & IP 70 For determination of viscosity of all oils the viscocity of which at the temperature of test exceeds 2000 seconds. Specification same as above but the cup and bath of No.2 viscometer are bigger than those of No.1.
OPTIONAL ACCESSORIES:
  • IP 8C Redwood Low range Thermometer
  • IP 9C Redwood Medium range Thermometer
  • IP 10C Redwood High range Thermometer
  • Flask Receiver 50 ml capacity.
  • Polish wooden case for Redwood No. 1
  • Spare Cup with valve for Redwood No. 1
  • Spare Cup with valve for Redwood No. 2
  • Polish wooden case for Redwood No. 2
  • Spare Heater for Redwood No. 1 Apparatus
  • Spare Heater for Redwood No. 2 Apparatus
  • Spare Ball Valve for Redwood No.1 and No. 2 Apparatus
  • Stop Watch Electronic Model
  • Stop Clock Table Model.